Infectious disease diagnostics

Vircell

Vircell, S.L. — Spain

Diagnostic solutions for human infectious diseases: chemiluminescence, immunofluorescence, agglutination serology and real-time PCR, supplied and serviced in Iraq by TMC.

Represented by TMC in IraqISO 13485ISO 9001ISO 14001CE marked
Vircell VirClia Lotus automated chemiluminescence analyser in use

VirClia Lotus40 results in 90 minutes, up to 94 markers

At a glance

About the manufacturer

Founded in 1991 in Granada, Vircell develops and manufactures ready-to-use reagents for the diagnosis of human infectious disease.

Its range runs from cell culture and immunofluorescence through to chemiluminescence and real-time PCR. The company produces its own antigens, operates BSL-3 facilities and exports to more than 95 countries across five continents.

Founded
1991, Granada
Reach
95+ countries
Manufacturing
In-house antigens, BSL-3
Menu
94 markers on VirClia

Why it matters for your laboratory

The VirClia monotest format removes the need for batching: each test carries its own calibrator and control, so a district hospital can run a single Brucella or H. pylori sample the moment it arrives, without waiting to fill a plate.

Coverage

Pathogen areas

Ten pathogen areas, from brucellosis and other zoonoses to respiratory, congenital and sexually transmitted infections.

  • Zoonoses (Brucella, Leptospira, Coxiella)
  • Respiratory bacteria and viruses
  • TORCH & congenital
  • Gastrointestinal infections
  • Vector-borne diseases
  • Sexually transmitted infections
  • Central nervous system
  • Mycobacterial infections
  • Viral hepatitis
  • Infectious mononucleosis

Products

Products we supply

Every instrument below is supplied, installed, calibrated and maintained by our own biomedical engineering team, with reagents and consumables delivered under a controlled cold chain.

VirClia Lotus

VirClia Lotus

Automated chemiluminescence for infectious serology

  • Up to 94 infectious disease markers in monotest format
  • 40 results in 90 minutes — first at about 70 minutes, then one every 35 seconds
  • 50 primary tubes and 50 dilution tubes; continuous loading
  • Random access with STAT priority and automatic predilution
  • 75 × 74 × 65 cm, up to 70 kg; 15.3-inch touchscreen, bidirectional LIS
Manufacturer page
VirClia Monotest

VirClia Monotest

Single-test chemiluminescence strips, ready to use

  • Every test carries its own calibrator and negative control
  • No batching — run one sample the moment it arrives
  • Result in approximately one hour on the VirClia Lotus
  • Typical pack size 24 tests; CE 0123 under IVDR
Manufacturer page
VIRPLEX MiniLab

VIRPLEX MiniLab

Sample-to-answer real-time PCR with integrated extraction

  • Up to 18 targets detected simultaneously
  • 90 minutes to result, under 2 minutes of hands-on time
  • Closed system — reduces contamination risk
  • STI panel includes Mycoplasma genitalium macrolide resistance
  • Swabs, urine and ulcer samples
Manufacturer page
VIRPLEX real-time PCR

VIRPLEX real-time PCR

Lyophilised multiplex PCR kits, room-temperature handling

  • Positive, negative and internal amplification controls included
  • Approximately 90 minutes to result
  • One common protocol lets different kits share a single run
  • Bio-Rad CFX96 and CFX96 Opus, Azure Cielo 6, QuantStudio 5
  • Regulatory status is per kit — some CE‑IVD, some research use only
Manufacturer page
PNEUMOSLIDE IgG / IgM

PNEUMOSLIDE IgG / IgM

Nine respiratory pathogens screened on a single slide

  • Legionella pneumophila SG1, Mycoplasma pneumoniae, Coxiella burnetii
  • Chlamydophila pneumoniae, Adenovirus, RSV
  • Influenza A and B, Parainfluenza 1, 2 and 3
  • Cell control included on every slide
  • IgG 20 tests, IgM 10 tests; CE marked
Manufacturer page
AMPLIRUN TOTAL

AMPLIRUN TOTAL

Molecular controls that cover extraction as well as amplification

  • Whole inactivated organism formulated in viral transport medium
  • Controls the complete workflow, not amplification alone
  • 10 single-use lyophilised vials per kit
  • Platform independent; quantified at low-positive levels
  • CE marked — unlike the AMPLIRUN purified controls, which are research use only
Manufacturer page

Product images are the property of the manufacturer and are reproduced here as their appointed distributor.

Brucellosis

From the card screen to chronic follow-up

Agglutination serology for brucellosis is first-line work in Iraqi public health laboratories. Vircell covers every step, from the rapid screen to confirmation and patient follow-up.

Screen: Rose Bengal

Rapid card agglutination with a coloured antigen suspension and an immediate result. 125 tests per kit, all reagents ready to use.

Confirm and follow up: Brucellacapt

Total anti-Brucella antibodies in a single immunocapture-agglutination step, for chronic brucellosis diagnosis and patient follow-up.

One sample at a time: VirClia

Positives can also be confirmed by ELISA or VirClia. With monotests, a district hospital can run a single Brucella sample as soon as it arrives.

Technology

Product families

The Vircell portfolio by technique, from single-test chemiluminescence to immunofluorescence, molecular quality control and cell culture.

VirClia Monotest

Single-test chemiluminescence strips, ready to use, each with its own calibrator and negative control. No batching, no manual pipetting on the analyser.

PNEUMOSLIDE IgG / IgM

One indirect immunofluorescence slide screening nine atypical pneumonia agents at once: Legionella pneumophila SG1, Mycoplasma pneumoniae, Coxiella burnetii, Chlamydophila pneumoniae, Adenovirus, RSV, Influenza A and B, Parainfluenza 1/2/3.

IFA & DFA

Immunofluorescence slides and direct fluorescent antibody reagents for Leishmania, Rickettsia, Coxiella, Legionella, Chlamydia and influenza.

VIRPLEX real-time PCR

Molecular kits for respiratory, gastrointestinal, STI and fungal targets, with matched nucleic acid extraction reagents.

AMPLIRUN & AMPLIRUN TOTAL

Lyophilised molecular quality controls. AMPLIRUN TOTAL uses whole inactivated organism in a clinical matrix to control extraction, amplification and detection together.

Cell lines & transport media

A-549, VERO and VERO E6 in flask, shell-vial, tube and suspension formats, plus CE-marked transport media.

Instruments

Instruments and software

We supply, install, calibrate and maintain these systems across all 18 governorates, with reagents and consumables delivered under a controlled cold chain.

VirClia Lotus

Automated chemiluminescence analyser covering up to 94 infectious disease markers in monotest format. 40 results in 90 minutes: first result at about 70 minutes, then one every 35 seconds. 50 primary tubes plus 50 dilution tubes, continuous loading, random access, STAT priority, automatic predilution and full barcode traceability.

VIRPLEX MiniLab

Sample-to-answer real-time PCR with integrated extraction: up to 18 targets simultaneously, closed system, about 90 minutes with under 2 minutes of hands-on time.

VIRCOM PCR

Middleware that centralises assay configuration, curve and Ct analysis, automatic interpretation and LIS connectivity over HL7 and ASTM.

Next step

Planning a laboratory, a tender or a replacement?

Send us the scope. We will come back with a configuration, a consumables projection and a service plan, not just a price list.